Esco Global » Biological Safety Cabinets » Labculture® Reliant Class II, Type A2 Biological Safety Cabinets

Labculture® Reliant Class II, Type A2 Biological Safety Cabinets

Labculture® Reliant Class II, Type A2 Biological Safety Cabinets Picture

The Safety Solution for Life Science Laboratories

Introducing the Esco Labculture Reliant - the best value Class II Biological Safety Cabinet on the North American market supported by nationwide sales and service representatives in the USA and Canada. The Reliant series is designed with a shorter height and smaller footprint for optimal utilization of lab space.

  • Certified to NSF 49 and UL 61010 for safety and performance.
  • The best value Class II Biological Safety Cabinet on the North American market supported by nationwide sales and service representatives in the USA and Canada.
  • The angled front, narrow-front grille, raised armrest and frameless sash create an ergonomic work environment.
  • Unique front grille designed to provide the maximum product and personnel protection.
  • Single-piece stainless-steel work tray and front grille, lower drain pan with angled side, and single-piece work zone liner eliminate joints for superior cleanability.
  • ULPA filters (per IEST-RP-CC-001.3) tested to a typical efficiency of >99.999% for 0.1 to 0.3 micron particles are better than HEPA filters. ULPA filters last as long as conventional HEPA filters and have similar replacement costs.
  • ISOCIDE antimicrobial coating on all powder coated surfaces eliminates 99.9% of surface bacteria within 24 hours of exposure.
  • Reliable rocker switches and Minihelic® pressure gauge.
  • Lowest height profile of any benchtop biological safety cabinet for the North American market.
  • Dual-wall construction surrounds the work zone with negative pressure plenums for maximum safety.
Model No. Standards Complied External
Dimensions (mm)
Internal
Dimensions (mm)
Airflow
Velocity (Inflow)
Airflow
Velocity (Downflow)
Electrical
LR2-4S2
ANSI/NSF49, EN 1822, EN12469, EN61010-1, IEC61010-1, IEST-RP-CC001.3, IEST-RP-CC007, IEST-RP-CC-034.1, ISO 14644.1, JIS B9920, JIS BS5295, JIS K3800, NSF49, SFDA, UL 61010A-1, US Federal Standard 209E, BS5295, CAN / CSA - C22-2 No. 61010-1
1340 x 762 x 1440
1216 x 570 x 670
0.53(m/s) /
105(fpm)
0.35(m/s) /
70(fpm)
110-120V,AC, 60Hz,1ø
LR2-6S2
ANSI/NSF49, EN 1822, EN12469, EN61010-1, IEC61010-1, IEST-RP-CC001.3, IEST-RP-CC007, IEST-RP-CC-034.1, ISO 14644.1, JIS B9920, JIS BS5295, JIS K3800, NSF49, SFDA, UL 61010A-1, US Federal Standard 209E, BS5295, CAN / CSA - C22-2 No. 61010-1
1950 x 762 x 1540
1826 x 570 x 670
0.53(m/s) /
105(fpm)
0.33(m/s) /
65(fpm)
110-120V,AC, 60Hz,1ø
UV lamp, service fixtures, support stands, electrical outlets, IV bar w/hooks, exhaust collars and ergonomic accessories.
Labculture® Reliant Class II, Type A2 Biological Safety Cabinets Airflow Picture
  • Ambient air is pulled through the perforations located towards the work zone front to prevent contamination of the work surface and work product. The inflow does not mix with the clean air within the cabinet work zone. Inflow air travels through a return path toward the common air plenum (blower plenum) at the top of the cabinet.
  • Approximately 40% of the air in the common plenum is exhausted through the ULPA filter to the room. The remaining 60% of the air is passed through the downflow ULPA filter and into the work area as a vertical laminar flow air stream bathing the work surface in clean air.
  • The uniform, non-turbulent air stream protects against cross contamination within and throughout the work area.
  • Near the work surface, the downflow air stream splits with a portion moving toward the front air grille, and the remainder moving to the rear air grille. A small portion of the ULPA filtered downflow enters the intake perforations at the side capture zones at a higher velocity (small blue arrows).
  • A combination of inflow and downflow air streams forms an air barrier that prevents contaminated room air from entering the work zone, and prevents work surface emissions from escaping the work zone.
  • Air returns to the common air plenum where the 40% exhaust and 60% recirculation process is continued.
STANDARDS COMPLIANCE MICROBIOLOGICAL SAFETY CABINETS AIR QUALITY FILTRATION ELECTRICAL SAFETY
NSF/ANSI 49, USA
JIS K3800, Japan
SFDA YY-D569, China
ISO 14644.1, Class 3, Worldwide
JIS B9920, Class 3, Japan
JIS BS5295, Class 3, Japan
US Fed Std 209E, Class 1 USA
EN-1822 (H14), Europe
IEST-RP-CCoo1.3, USA
IEST-RP-CC007, USA
IEST-RP-CC034.1, USA
UL 61010-1, USA
CAN/CSA-22.2, No.61010-1
EN 61010-1, Europe
IEC 61010-1, Worldwide